3/2-way valve, Series DO22
▶ Qn = 48 l/min ▶ plate connection ▶ Electr. connection: Plug, ISO 6952, form B ▶ Manual override: with detent, without
|
|
|
|
|
| Version |
Poppet valve |
| Sealing principle |
soft sealing |
| Mounting on manifold strip |
PRS strip |
| Working pressure min./max. |
See table below |
| Ambient temperature min./max. |
-10°C / +50°C |
| Medium temperature min./max. |
-10°C / +50°C |
| Medium |
Compressed air |
| Max. particle size |
5 µm |
| Oil content of compressed air |
0 mg/m³ - 5 mg/m³ |
| |
| Degree of protection with electrical connector/plug |
IP 65 |
| Compatibility index |
See table below |
| Duty cycle |
100 % |
| Mounting screw |
M3 |
| Housing |
Plastic |
| Seals |
Fluorocaoutchouc |
|
|
|
|
 |
| ■ |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C. |
| ■ |
The oil content of compressed air must remain constant during the life cycle. |
| ■ |
Use only the approved oils from Bosch Rexroth, see chapter „Technical information“. |
|
24 V
|
-
|
-10% / +10%
|
-
|
2,6
|
-
|
-
|
|
24 V
|
-
|
-10% / +10%
|
-
|
4,8
|
-
|
-
|
|
-
|
230 V
|
-
|
-10% / +10%
|
-
|
11
|
8,5
|
|
|
|
24 V
|
-
|
-
|
-
|
48
|
56
|
2 / 7
|
13
|
2)
|
|
|
0 / 10
|
14
|
-
|
|
|
|
|
-
|
-
|
-
|
-
|
48
|
56
|
0 / 10
|
14
|
1); 1); 3)
|
|
|
|
-
|
24 V
|
-
|
-
|
-
|
48
|
56
|
2 / 7
|
13
|
2)
|
|
|
0 / 10
|
14
|
-
|
|
|
|
-
|
-
|
-
|
-
|
-
|
48
|
56
|
0 / 10
|
14
|
1); 1); 3)
|
|
|
|
|
24 V
|
-
|
-
|
-
|
48
|
56
|
0 / 10
|
14
|
-
|
|
|
-
|
230 V
|
8,5
|
11
|
|
|
|
-
|
-
|
-
|
-
|
-
|
48
|
56
|
0 / 10
|
14
|
1); 3)
|
|
|
|
|
|
|
|
|
 |