Pneumatic sensor, Series SP1
▶ Qn = 40 l/min ▶ Mounting orientation: Any
|
|
|
|
|
| Ambient temperature min./max. |
-15°C / +60°C |
| Medium |
Compressed air |
| Max. particle size |
40 µm |
| Oil content of compressed air |
0 mg/m³ / 0,1 mg/m³ |
| Working pressure min./max. |
2 bar / 6 bar |
| Switching point precision |
±0,2 |
| Switching time on |
12 ms |
| Switching time off |
25 ms |
|
|
|
|
 |
| ■ |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C. |
| ■ |
The oil content of compressed air must remain constant during the life cycle. |
| ■ |
Use only the approved oils from Bosch Rexroth, see chapter „Technical information“. |
| ■ |