Bosch Rexroth
www.rexrothpneumatics.com
Search Search   Contact Contact   Sitemap Sitemap   Shopping basket Shopping basket  

DDL-X-Tool, V-design
▶ Optional tool to simplify commissioning of DDL components
 
Ambient temperature min./max. +5°C / +50°C
Protection class, with plug IP 20
Operational voltage electronics 24 V DC
Electronics voltage tolerance -20% / +20%
Operational voltage valves 24 V DC
Total output for valves 2,5 A
Search in catalog
Search

Advanced search
Documentation

Data sheet

Operating Instructions

GSD/EDS files
Technical Remarks
The DDL-X-Tool is used to test and control DDL components, if field bus communication is not yet available (master function), or for observation purposes during field bus operation (viewer function).
Suitable for all DDL components from Bosch Rexroth.
A PC is required for operation.
System requirements: PIII processor with 800 MHz, 256 MB RAM, USB interface, CD-ROM drive, Microsoft Windows 98SE, 2000, or XP operating system.
The DDL-X-Tool is a diagnostic tool and should not permanently remain in the DDL line.

Weight
Part No.
[kg]
 
3,1
Scope of delivery:
1 DDL-X-Tool
1 USB adapter
1 USB adapter manual
1 driver CD-ROM
1 installation manual
1 9-pin D-SUB cable, 1 m
1 power pack 24 V DC, 2.5 A
3 mains plug cables for the power pack (EU, GB, US)
1 CD-ROM with software for DDLfWin master, DDLfWin viewer and operating instructions
1 DDLfWin installation instructions
1 case with foam inlay


DDL-X-Tool connections
1) Integrated plug (DDL line coming from the bus module)
2) Selector switch (master/viewer mode)
3) LED
4) LED
5) D-Sub plug (PC connection)
6) Integrated socket (DDL ling going to the modules)
7) Mains connection socket (for DDL supply of electronics and valves)
8) Integrated socket (separate supply for electronics, alternative to 7)
9) Integrated socket (separate supply for valves, emergency OFF, alternative to 7)
10) Integrated socket (ground, alternative to 7)


Master function to simplify commissioning
1) Power pack
2) Electronics 24 V/valves 24 V
3) Bus module
In the master function, all outputs from the components in the DDL line can be controlled and all inputs are visible.


Viewer function for observation purposes during field bus operation
1) Electronics 24 V/valves 24 V
2) Field bus
3) Bus module
In the viewer function, the DDL-X-Tool displays all inputs and outputs from the components in the DDL line.




JavaScript is not activated in your browser.
This may result in functional restrictions.




Supplementary products
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online version, as of 2013-06-19, © Bosch Rexroth Pneumatics GmbH, subject to change