2x3/2-way valve, Series HF03-LG, CL03, CL03-XL
▶ Qn = 850 l/min ▶ plate connection ▶ Manual override: without detent
|
|
|
|
|
| Version |
Spool valve, zero overlap |
| Pilot |
external, internal |
| Sealing principle |
soft sealing |
| Blocking principle |
Single base plate principle |
| Working pressure min./max. |
-0,9 bar / 10 bar |
|
Control pressure
min./max.
|
2,5 bar / 10 bar |
| Ambient temperature min./max. |
+0°C / +50°C |
| Medium temperature min./max. |
+0°C / +50°C |
| Medium |
Compressed air |
| |
| Degree of protection with electrical connector/plug |
IP 65 |
| Protective circuit |
Z-diode |
| |
Protected against polarity reversal |
| Status display LED |
Yellow |
| Duty cycle |
100 % |
| Switch-on time |
16 ms |
| Switch-off time |
25 ms |
| Generic emission standard in accordance with |
EN 50081-1 |
| Generic immunity standard in accordance with |
EN 50082-2 |
| Mounting screw |
cross recessed DIN EN ISO 4757-Z1 |
| mounting screw tightening torque |
1,3 Nm |
| Weight |
0,082 kg |
| Housing |
Polyamide, fiber-glass reinforced |
| Seals |
Acrylonitrile Butadiene Rubber |
|
|
|
|
 |
| ■ |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C. |
| ■ |
The oil content of compressed air must remain constant during the life cycle. |
| ■ |
Use only the approved oils from Bosch Rexroth, see chapter „Technical information“. |
| ■ |
The pilot type (external/internal) is not implemented in the valve, but in the end plate of the valve system. |
| ■ |
The pilot valve is UL (Underwriters Laboratories) certified. |
|
|
NC/NC
|
|
24 V
|
0,22
|
2,97
|
850
|
|
|
|
NO/NO
|
|
24 V
|
0,22
|
2,97
|
850
|
|
|
|
NC/NO
|
|
24 V
|
0,22
|
2,97
|
850
|
|
|
|
NO/NC
|
|
24 V
|
0,22
|
2,97
|
850
|
|
|
|
|
|